Pulmonary vs. Systemic Circulation for the MCAT

Trace blood through the pulmonary and systemic circuits, compare pressure and oxygen levels, and use vessel direction to avoid common circulation errors.

Updated . Sources

On this page

The right side of the heart sends oxygen-poor blood to the lungs, where it gains oxygen, and the left side sends oxygen-rich blood to the body's tissues. These two connected loops are pulmonary and systemic circulation, respectively. Arteries carry blood away from the heart and veins carry it toward the heart, regardless of how much oxygen the blood contains.

Prerequisites: Know the heart's four chambers and valves; review heart structure and function if needed. For vessel structure, see arterial and venous systems.

Pulmonary and systemic circulation

Trace the two circuits

The heart works as two pumps connected in series. The right ventricle drives blood through the pulmonary circuit, which runs between the heart and lungs; the left ventricle drives blood through the systemic circuit, which supplies the rest of the body. Blood leaving either pump eventually returns to the opposite side of the heart, so the two loops form one continuous route rather than separate pools.

Trace one complete trip in two parts:

  • Through the lungs: right atrium → tricuspid valve → right ventricle → pulmonary valve → pulmonary trunk → pulmonary arteries → lung capillaries → pulmonary veins → left atrium.
  • Through the body: left atrium → mitral valve → left ventricle → aortic valve → aorta → systemic arteries → arterioles → tissue capillaries → venules → systemic veins → superior and inferior venae cavae → right atrium.

The valves prevent backflow. In lung capillaries, blood releases carbon dioxide and gains oxygen; in systemic capillaries, it delivers oxygen and receives carbon dioxide from metabolizing tissues. For how hemoglobin loads and unloads oxygen, see oxygen transport by blood.

A heart divided into right and left compartments connects lung and body loops. Blue arrows lead from the right heart to the lungs and from the body back to the right heart; red arrows lead from the lungs to the left heart and from the left heart to the body. A heart divided into right and left compartments connects lung and body loops. Blue arrows lead from the right heart to the lungs and from the body back to the right heart; red arrows lead from the lungs to the left heart and from the left heart to the body. Double circulation Lungs Right heart Left heart Body tissues Pulmonary circuit · lower pressure Systemic circuit · higher pressure Pulmonaryarteries Pulmonaryveins Systemicveins Systemicarteries Oxygen-poor Oxygen-rich
The right heart sends oxygen-poor blood through the lower-pressure pulmonary circuit to the lungs; oxygen-rich blood returns to the left heart and travels through the higher-pressure systemic circuit to body tissues.

Same flow, different pressure

The pulmonary circuit operates at lower pressure because its vascular resistance is lower than systemic resistance. Distance alone does not determine the pressure needed: vessel radius and the arrangement of vessels also affect resistance.

Blood flow follows Q=ΔP/RQ=\Delta P/R, where QQ is volume per time, ΔP\Delta P is the pressure drop across a circuit, and RR is its resistance. At the same flow, a lower resistance requires a smaller pressure difference. The right ventricle therefore drives pulmonary flow with a smaller pressure difference than the left ventricle uses for systemic flow.

Because the circuits are connected in series, their average flows must match at steady state. If one ventricle temporarily pumps more than the other, blood accumulates between them. Equal flow does not mean equal pressure or equal blood volume in the two circuits.

Oxygen content does not define an artery

An artery is a vessel carrying blood away from the heart; a vein carries blood toward it. This definition works in both loops, even though the oxygen levels of pulmonary vessels reverse the familiar systemic pattern. Pulmonary arteries leave the right ventricle carrying oxygen-poor blood to the lungs, and pulmonary veins return oxygen-rich blood to the left atrium. In systemic circulation, arteries generally carry oxygen-rich blood away from the left ventricle, while veins return oxygen-poor blood to the right atrium.

Circuit Vessel leaving heart Vessel returning to heart Pressure level
Pulmonary Pulmonary artery, oxygen-poor Pulmonary vein, oxygen-rich Lower
Systemic Systemic artery, oxygen-rich Systemic vein, oxygen-poor Higher

Oxygen-poor blood still contains oxygen; the term describes its lower oxygen content relative to oxygen-rich blood. When identifying an unfamiliar vessel, first trace whether it leads away from or toward the heart. Then locate the gas-exchange bed to determine its oxygenation.

Worked example: predict where blood accumulates

Cardiac output is the volume a ventricle ejects per minute:

CO=HR×SVCO=HR\times SV

Heart rate (HRHR) has units of beats/min, and stroke volume (SVSV) has units of L/beat. Their product has units of L/min.

At the original steady state, whole-body flow is 5.4 L/min, not 10.8 L/min: the two ventricles pump the same circulating blood in sequence, so you do not add their outputs. Matching average output also does not require equal chamber volumes at every instant. The right and left ventricles normally contract during the same phase of the cardiac cycle.

Traps

  • Wrong: every artery carries oxygen-rich blood. Correct: arteries carry blood away from the heart; the pulmonary artery carries oxygen-poor blood because it runs from the right ventricle to the lungs.
  • Wrong: every vein carries oxygen-poor blood. Correct: veins return blood to the heart; pulmonary veins return oxygen-rich blood from the lungs to the left atrium.
  • Wrong: lower pulmonary pressure means less blood flows through the lungs. Correct: the circuits carry equal average flow at steady state; lower pulmonary resistance allows that flow with a smaller pressure difference.
  • Wrong: the two sides can maintain different average outputs indefinitely. Correct: the circuits are connected in series, so sustained unequal outputs would cause blood to accumulate in one circuit.

Study the whole MCAT with Wizeprep

Try sample video lessons, AAMC-style practice passages and a practice test for free.

Get Started for Free