Venturi Effect and Pitot Tubes

See why static pressure drops at a Venturi throat and how to calculate flow speed from a pitot tube’s pressure readings using Bernoulli’s equation.

Updated . Sources

On this page

In steady, incompressible flow through a horizontal Venturi tube, fluid speeds up and its static pressure falls at the narrow throat when energy losses are small. A pitot tube measures speed by comparing the pressure where the fluid comes to rest with the static pressure of the nearby flow.

Review the continuity equation for how area sets speed and Bernoulli’s equation for how speed, height, and pressure are related.

Venturi and pitot measurements

Venturi effect

In a single unbranched pipe, the same volume of fluid passes each cross-section per second in steady, incompressible flow. The continuity equation is A1v1=A2v2A_1v_1=A_2v_2, where AA is cross-sectional area in m2^2 and vv is speed in m/s. Half the area means twice the speed.

For steady, incompressible flow with negligible energy losses, Bernoulli’s equation gives the energy balance along a streamline.

P+12ρv2+ρgh=constant.P+\frac12\rho v^2+\rho gh=\text{constant}.

Here PP is static pressure (Pa), ρ\rho is density (kg/m3^3), vv is speed (m/s), gg is gravitational acceleration (m/s2^2), and hh is height (m). Every term has units of pressure, equivalent to energy per unit volume. At the throat of a horizontal pipe, the height term stays the same while the kinetic term increases. Static pressure falls to keep the sum constant.

A wall tap samples static pressure. If equal-height taps feed two separate open columns of the pipe liquid, the higher pressure supports the taller column and the pressure difference has magnitude ρgΔh\rho g\Delta h, where Δh\Delta h is the difference in column heights.

In a connected U-tube with a denser manometer liquid, higher pressure pushes the interface down on that side. For equal-height taps, the magnitude of the pressure difference is (ρm−ρ)gΔh(\rho_m-\rho)g\Delta h. Here ρm\rho_m is the manometer liquid density, ρ\rho is the pipe fluid density, and Δh\Delta h is the vertical gap between the interfaces.

For two points at the same height, Bernoulli’s equation can be rearranged to compare pressures directly:

P1−P2=12ρ(v22−v12).P_1-P_2=\frac12\rho(v_2^2-v_1^2).

If point 2 is the throat, v2>v1v_2>v_1 and P1>P2P_1>P_2. A Venturi meter uses that static pressure difference, the known cross-sectional areas, and the fluid density to infer flow speed.

Top view of a horizontal pipe carrying fluid from left to right. Wall taps mark higher static pressure in the wide section and lower static pressure at the throat, where the flow arrow is longer. The pitot opening faces left into the throat flow and marks the point where fluid comes to rest. Top view of a horizontal pipe. Fluid flows from the wide section into a narrow throat, where it moves faster and has lower static pressure. Sidewall taps sample static pressure in both sections. A pitot opening faces upstream at the throat and samples stagnation pressure where the incoming fluid comes to rest. Schematic · top view Wide section Higher static pressure Throat Lower static pressure Slower Faster Upstream-facing pitot tip Stagnation pressure · v = 0
In steady, incompressible flow with negligible losses, the horizontal throat has faster flow and lower static pressure. The difference between the pitot tip’s stagnation pressure and the throat’s static pressure gives the local flow speed.

Pitot tube

The pitot opening faces upstream. Fluid on the streamline aimed into the opening comes to rest at the tip, creating a stagnation point. At equal height and with negligible losses, the drop in kinetic energy per unit volume equals the rise in pressure. This pressure difference is the dynamic pressure.

Pstag−Pstatic=12ρv2.P_{stag}-P_{static}=\frac12\rho v^2.

A pitot-static probe samples stagnation pressure PstagP_{stag} at its forward-facing port and local static pressure PstaticP_{static} at its side ports. Subtract the readings, then use the fluid density to find speed with v=2(Pstag−Pstatic)/ρv=\sqrt{2(P_{stag}-P_{static})/\rho}.

Instrument Pressure readings How you infer speed
Venturi meter Static pressure in the wide section and at the throat Use continuity to relate the two moving speeds, then use Bernoulli’s equation
Pitot-static probe Stagnation pressure at the tip and local static pressure Use Bernoulli’s equation with zero speed at the tip

Worked example: speed and pressure in a narrowed artery model

Water (ρ=1,000\rho=1{,}000 kg/m3^3) flows through a horizontal tube that models a narrowed artery. The upstream section has twice the cross-sectional area of the throat. A pitot-static probe at the throat reads 1,500 Pa at its forward-facing port and 1,000 Pa at its side ports. Both are gauge pressures. Find the throat speed and the upstream static pressure. Assume steady flow with negligible energy losses.

MCAT traps

  • Predict the sign before you calculate. In a horizontal Venturi tube with negligible losses, the throat has the higher speed and the lower static pressure.
  • Check the elevations and losses. If the points differ in height, keep the ρgh\rho gh terms. When viscous or turbulent losses are appreciable, the ideal Bernoulli equation can misestimate the pressure difference.
  • Track the square. At the same fluid density, doubling the speed quadruples the pitot pressure difference.
  • Check what stays fixed. Continuity gives the same volume flow rate at each cross-section of one unbranched pipe in steady, incompressible flow. Two different pipes driven by the same pressure difference can have different flow rates.

Return to the Fluids overview, or use Poiseuille flow to see how viscosity and tube size affect the flow rate in a long cylindrical tube with steady laminar flow.

Study the whole MCAT with Wizeprep

Try sample video lessons, AAMC-style practice passages and a practice test for free.

Get Started for Free