On this page
A mercury barometer measures atmospheric pressure using the vertical height of a mercury column above an open reservoir. When the pressure above the column is negligible, atmospheric pressure equals the column's weight per unit area. Higher atmospheric pressure supports a taller column at the same mercury density and gravity.
Pressure is force per unit area (). In a liquid at rest, pressure increases with depth.
How a Mercury Barometer Works
Fill a tube sealed at one end with mercury and invert it with the open end submerged in a mercury reservoir. Some mercury drains into the reservoir, leaving a low-pressure space above the column. Outside air presses on the exposed reservoir surface, and the submerged opening keeps the mercury in the tube connected to the reservoir.
Picture a horizontal line at the reservoir surface. At that level, the pressure inside the tube equals atmospheric pressure at the exposed surface because the mercury is connected and at rest. As you go up from that level to the top of the column, the pressure drops by the weight of the column per unit area. For a tube of cross-sectional area , the column of height weighs . Dividing by gives the pressure difference .
Taking mercury density and gravitational acceleration as constant over the column gives:
Here is the pressure in the space above the mercury. In a simple barometer, that space contains mercury vapor at low pressure. When is negligible, use .
The sealed end lets the pressure above the column stay well below atmospheric pressure. If you open that end to room air, the same atmospheric pressure acts on both mercury surfaces. With no pressure difference to support a raised column, the surfaces settle at the same level when capillary effects are negligible.
Column height and pressure units
Measure vertically from the reservoir surface to the mercury surface in the tube. When you calculate with density in kg/m, gravity in m/s, and height in meters, the result is a pressure difference in pascals (Pa).
The unit mmHg expresses pressure as the equivalent height of a mercury column. With negligible pressure at the top, a reading of about 760 mm in a calibrated mercury barometer corresponds to 1 atm. For MCAT calculations, use .
For a fixed pressure difference and gravity, a denser liquid reaches equilibrium at a shorter height. Mercury's high density keeps the instrument compact. Stronger gravity also shortens the column for the same pressure difference and liquid density.
Suppose a barometer uses a liquid with half the density of mercury. With negligible pressure above both columns, the lighter liquid needs twice the height to balance the same atmospheric pressure. If you report the result in mmHg, use the equivalent mercury height. The two instruments have different column heights and measure the same pressure.
Worked example with trapped air
Traps
- Measure straight up. Mark the exposed reservoir surface and the mercury surface in the tube. Use the vertical gap between them even if the tube is tilted or its opening is deep in the reservoir.
- Check which pressure changed. At fixed mercury density and gravity, a shorter column means a smaller pressure difference. Either a drop in atmospheric pressure or a rise in pressure at the top can shorten the column.
- Check the role of tube width. A wider tube holds more mercury at the same height, but spreads its weight over a larger area. The equilibrium height is independent of width when capillary effects are negligible. In a very narrow tube, capillary effects can shift the reading.
The Gas Phase topic page connects barometer pressure to gas laws and partial pressure. For pressure assigned to one gas in a mixture, continue to Partial pressure, mole fraction.