Visible Light Absorption, Color, and Indicators

Learn why beta-carotene looks orange, how conjugation affects visible light absorption, and how pH changes the color of acid-base indicators in titrations.

Updated . Sources

On this page

Under white light, a pigment often looks roughly complementary to the color it absorbs most strongly. Beta-carotene absorbs strongly in the blue part of the spectrum and looks orange. An acid-base indicator changes color because pH changes the balance between forms that absorb light differently.

Start with two ideas. Shorter-wavelength photons carry more energy, and a weak acid can lose a proton to form its conjugate base.

Complementary colors and beta-carotene

Visible light spans roughly 400 to 700 nm. A pigment takes some wavelengths out of the light that hits it. You see the mix that passes through a solution or reflects from a surface. Under white light, blue absorption can leave an orange appearance, as in beta-carotene. Use the complementary color as a first estimate when one part of the spectrum is absorbed much more strongly. The exact hue depends on the whole spectrum that reaches your eye.

On a UV-Vis spectrum, wavelength is on the horizontal axis and absorbance is on the vertical axis. For a clear solution, higher absorbance means less light passes through at that wavelength. Find λmax⁡\lambda_{\max} by reading the wavelength at the top of the absorption band. If the strongest absorption lies in the UV, check for other bands in the visible range before predicting a color.

How conjugation shifts absorption

A molecule absorbs a photon when its energy matches an electronic transition. The energy gap ΔE\Delta E and the absorbed wavelength λ\lambda are related by ΔE=hf=hc/λ\Delta E=hf=hc/\lambda, where hh is Planck’s constant, ff is the photon frequency, and cc is the speed of light. A smaller gap corresponds to a longer wavelength.

In a conjugated system, adjacent p orbitals overlap and let π electrons spread across several atoms. Extending conjugation usually narrows the energy gap in otherwise comparable molecules. A band can then shift from the UV into the visible range. Beta-carotene’s 11 conjugated double bonds provide a long stretch of overlapping orbitals, which helps explain its visible absorption. A shift to longer wavelengths is a red shift (bathochromic shift). A shift to shorter wavelengths is a blue shift (hypsochromic shift).

Why pH indicators change color

Gaining or losing a proton can change the way electrons are distributed in an indicator. If the change alters conjugation, it can shift an absorption band enough to change the color. In phenolphthalein’s usual indicator range, the colorless form has a closed ring. As pH rises through the transition, a ring-opened form with more extended conjugation gives the solution a pink color.

For a simple one-proton indicator, the equilibrium is HIn⇌H++In−\mathrm{HIn} \rightleftharpoons \mathrm{H^+} + \mathrm{In^-}. Raising pH favors the deprotonated form, In−\mathrm{In^-}. Lowering pH favors the protonated form, HIn\mathrm{HIn}. The Henderson–Hasselbalch equation gives the ratio:

pH=pKa+log⁡10([In−][HIn])\mathrm{pH} = \mathrm{p}K_a + \log_{10}\left(\frac{[\mathrm{In^-}]}{[\mathrm{HIn}]}\right)
pH compared with the indicator’s pKa\mathrm{p}K_a Approximate ratio [In−]:[HIn][\mathrm{In^-}]:[\mathrm{HIn}] Form in greater abundance
One unit below 1:10 Protonated
Equal 1:1 Both have equal concentrations
One unit above 10:1 Deprotonated

A shift of one pH unit changes the ratio tenfold. As the ratio changes, so does each form’s contribution to the solution’s color. About one pH unit on either side of the indicator’s pKa\mathrm{p}K_a is a useful estimate of its transition range.

An illustrative weak-acid titration curve rises as strong base is added. Equivalence lies above pH 7 on the steep part of the curve, within the shaded indicator transition range. An illustrative plot of pH against volume of added strong base. The curve rises gradually, then steeply through the shaded indicator transition range, then levels off. The equivalence point is on the steep rise above pH 7. Weak acid titrated with strong base Illustrative titration curve Indicator transition range pH 7 Equivalence Volume of strong base added (mL)
Choose an indicator whose color transition falls within the steep pH rise around equivalence. A small addition of titrant there produces a large change in pH.

Choosing a titration indicator

Choose an indicator whose color transition falls within the steep pH change around equivalence. At the equivalence point, you’ve added the amount of titrant required by the balanced reaction. The endpoint is the point where you observe the specified color change, such as the first persistent tint. In a weak-acid titration with a strong base, the conjugate base makes the solution basic at equivalence. An indicator that completes its transition well into the acidic range can signal the endpoint too early.

Worked example with phenolphthalein

MCAT traps

  • A red shift describes absorption. Read it as a move to a longer absorbed wavelength. The band can shift to a longer wavelength and still remain in the UV.
  • Conjugation needs continuous overlap. An sp3sp^3 carbon between two double bonds interrupts their p-orbital overlap. Trace the connected system before predicting a shift.
  • Equal concentrations can give unequal color contributions. At pH=pKa\mathrm{pH}=\mathrm{p}K_a, the two forms of a simple indicator are equally abundant, but one form can absorb visible light more strongly.

Keep studying

Review the spectroscopy overview, then connect visible absorption to UV electronic transitions or compare it with infrared absorption and bond vibrations.

Study the whole MCAT with Wizeprep

Try sample video lessons, AAMC-style practice passages and a practice test for free.

Get Started for Free