On this page
Sound intensity is the power a sound wave carries per unit area. Sound intensity level, measured in decibels (dB), puts that intensity on a logarithmic scale relative to a reference. A rise of 10 dB means ten times the intensity, whatever the starting level.
Prerequisites: Sound waves carry energy through a medium. Review production of sound for how vibrating sources create sound waves.
Sound intensity and decibels
If sound power passes uniformly through an area perpendicular to the direction of travel, the intensity is , measured in watts per square meter (). If the same power spreads over twice the area, each square meter receives half as much power.
The sound intensity level is given by
Here, is in dB and is the conventional reference in air, near the threshold of hearing for a 1 kHz tone. Use the same units for and so they cancel inside the logarithm.
In the graph, both a rise from 0 to 10 dB and a rise from 30 to 40 dB move up one gridline. The vertical axis is logarithmic, so each gridline represents a tenfold increase in . Equal steps in dB multiply intensity by the same factor.
At , the ratio is 1 and the level is 0 dB. Below the reference, the ratio is between 0 and 1. For example, gives dB. The intensity is still positive.
Compare two sound levels
When two levels use the same reference, subtract the first from the second. The quotient rule for logarithms cancels .
To recover the intensity ratio, divide the level difference by 10 and use it as the exponent of 10.
| Level change, | Final intensity / initial intensity |
|---|---|
| −20 dB | |
| −10 dB | |
| 0 dB | |
| +10 dB | |
| +20 dB |
Worked example with a moving sound meter
A small speaker radiates sound equally in every direction at constant power. A sound meter reads 70 dB at 2 m, then moves to 6 m from the speaker. Assume reflections and absorption are negligible.
Sound intensity can fall with distance even when the medium absorbs no sound. In this example the same power spreads over a larger area. If the medium also absorbs sound, less power reaches the outer sphere, so the level drops further.
Combine independent sound sources
At a detector, add the intensities from independent sources because their interference averages out. If you start with dB readings, convert each to intensity using and add the intensities before converting the total back to dB. Waves that maintain a fixed phase relationship can reinforce or cancel at the detector, so their combined intensity depends on how they overlap.
Worked example: Two fans at one detector
Two independent ventilation fans each register 60 dB at the same detector when run alone. Background sound is negligible. What intensity and level will the detector register when both fans run?
Intensity and perceived loudness
Loudness is how strong a sound seems to a listener. Two tones at the same intensity level can sound different in loudness because the ear is more sensitive to some frequencies than others. Use the decibel equation to compare physical intensities.
MCAT traps
- Keep the order straight. If the second reading is lower, is negative and must be below 1. A ratio above 1 tells you the order got flipped.
- Distinguish a reading from a change. A reading of 0 dB means . A change of 0 dB means the two intensities are equal at any level.
- Estimate the ratio before calculating. A 15 dB rise falls between 10 and 20 dB, so the intensity must increase by a factor between 10 and 100.
Return to Sound or continue to sound attenuation to see how a medium reduces sound intensity.